Foster® Sealfas G-P-M® Mastic 35-00™

1 of 92 products in this brand
Foster® Sealfas G-P-M® Mastic 35-00™ is a high-solids, water-based, general purpose mastic known for its superb trowel and spray capabilities. This product is utilized for safeguarding thermal insulation and hard, dry cement coatings, suitable for both indoor and outdoor applications.

Product Type: Waterborne Adhesive

Application Area: Brush

Application Method: Spray, Trowel

Features: Ease Of Use, Fire-Resistant, High Solids Content, Outdoor Durability, Thermally Insulating, Water-based

Enhanced TDS

Identification & Functionality

Features & Benefits

Labeling Claims
Ready-to-Use Product Features
Product Highlights
  • Foster® Sealfas G-P-M® Mastic is a high solids, water-based, general purpose mastic having excellent trowel and spray properties.
  • G-P-M® is used for the protection of thermal insulation and hard, dry cement coats, both indoors and outdoors.
  • Sealfas G-P-M® Mastic is fire-resistive and features ease of application, non-flammability, non-toxicity, mild odor, insulation compatibility, good package stability, plus excellent outdoor durability.
  • Sealfas G-P-M® Mastic meets NFPA 90A & 90B 25/50 requirements.
  • Sealfas G-P-M® Mastic is produced under the classification and follow-up service of Underwriter's Laboratories, Inc. Nuclear Grade
  • Sealfas G-P-M® Mastic 35-00Q can be supplied to meet the stress corrosion and chemical analysis requirements of MIL-I-24244C or nuclear regulatory guide 1.36 on special order.
  • Sealfas G-P-M® Mastic 35-00 meets the requirements of:
    • MAS Certified Green®
    • California Dept. of Public Health Standard Method v1.2
    • VOC Emissions and Content requirements to contribute to LEED v4 EQ Credit: Low Emitting Materials – Paints and Coatings

Applications & Uses

Application Area
Application Method
Preparation and Application Information

Preparation

  • Do not thin.
  • Foster® Sealfas G-P-M® Mastic will appear to be thick, but this is a "false" consistency which "breaks down" readily on application.
  • Stirring is not necessary. Apply only to clean, dry, oil-free surfaces.
  • Keep container closed when not in use.

Application – heavy duty, hot and dual temperature service

  • Follow flashing recommendations when installed outdoors.
  • For best results, prime hygroscopic alkaline cements with Foster® 32-22 Protektor® Sealant or Foster 81-42W LAGFAS® Adhesive/Coating diluted 50% with water to lock down dusty surfaces.
  • Both the cement and the primer must be completely dry before the Foster® Sealfas G-P-M® Mastic is applied.

MAST-A-FAB® Reinforcement

  • Apply a tack coat of Foster® Sealfas G-P-M® Mastic at a thickness of 1/32 inch (0.8 mm).
  • This is equivalent to 2 gal./100 sq. ft. (0.8 l/m2 ). Embed Foster® Mast-A-Fab® white membrane into wet tack coat.
  • Smooth membrane to avoid wrinkles and overlap all seams at least 2 inches (5 cm).
  • Apply a finish coat of Foster® Sealfas G-P-M® Mastic at a minimum thickness of 1/16 inch (1.6 mm).
  • This is equivalent to 4 gal./100 sq. ft. (1.6 l/m2 ).
  • This finish coat shall be applied no later than 1/2 hour after the tack coat and shall completely cover the membrane.
  • This application shall provide a minimum dry film thickness of 62 mils (1.6 mm).

Heavy duty applications – up to 50% greater tensile strength

  • Apply as above, substituting Childers™ Chil-Glas® #5 as the reinforcing membrane.
  • Note that the membrane weave pattern will show through the dried mastic.

Trowel

  • Use clean steel trowel.
  • Apply in full thickness promptly.
  • Avoid excessive troweling.

Brush

  • Use a good brush (suitable for water-based paints), making strokes as long as possible over the surface.
  • Apply with full brush and spread out evenly.
  • Do not overwork.
  • Multiple coats will be needed to achieve the minimum dry film thickness.

Spray

  • Foster® Sealfas G-P-M® Mastic (45-00™ series) may be spray applied with heavy duty pneumatic airless equipment.
  • For spray equipment information, please consult Airless Spray Recommendations or contact your spray equipment supplier.
  • Average viscosity range: 60,000 – 100,000 cps.
  • Corrosion resistant pumps and fittings are suggested.
Cleaning Information
  • Use fresh water to clean equipment before product dries.
  • Dry product may be removed with hot soapy water or solvents such as chlorinated solvent (non-flammable) or xylol (flammable).

Properties

Physical Form
Typical Properties
ValueUnitsTest Method / Conditions
Average Weight / U.S. Gallon1.39kg/lASTM D1475
Average Non-Volatile (by Volume)63 - 65% ASTM D2369
Average Non-Volatile (by Weight)73 - 75% ASTM D2369
Coverage Range6.0gal./100 sq. ft-
Drying Time (Set to Touch)3.0Hours-
Drying Time (Dry Through)16.0Hours-
Water Vapor Permeance3.0PermsASTM F1249
Wet Flammability96.0°C-
Application Properties
ValueUnitsTest Method / Conditions
Service Temperature Range-29 to 93°C-
Flame Characteristics
ValueUnitsTest Method / Conditions
Surface Flame Spread20.0-ASTM E84
Smoke Developed25 - 50-ASTM E84

Regulatory & Compliance

Storage & Handling

Shelf Life
12 months
Handling Conditions
  • Store and apply between 40°F (4°C) and 100°F (38°C), protect from freezing until dry.
  • To resist rain washoff, allow at least 16 hours drying time above 40° F (4°C), with a relative humidity of 50%.
  • Higher humidity at lower temperatures may retard drying. Always test paper facings for acceptable adhesion before using.
  • Outdoor horizontal surfaces must always drain completely.
  • A pitch of at least 1/2 inch per foot (4 cm/m) is recommended.
  • Always select Foster® Sealfas G-P-M® Mastic 35-00/45-00™ white for use over polystyrene insulation installed outdoors.