Enhanced TDS
Identification & Functionality
- Chemical Family
- Product Type
- Technologies
- Product Families
Features & Benefits
- Ready-to-Use Product Features
- General Information about MMA adhesives
2-component methacrylate adhesives belong to the group of reactive adhesives. The reaction starts by mixing hardener and resin. Cyberbond offers these adhesives in double cartridges in 1:1 or 10:1 ratio with static mixing tubes. This allows an easy and quick application. Methacrylate adhesives are available in different viscosities from liquid to paste-like and with different curing times. They are characterized by excellent adhesion to metals, many plastics and composite materials. The mechanical properties range from flexible to rigid.
Applications & Uses
- Markets
- Applications
- Compatible Substrates & Surfaces
- Clean Surface
Surfaces should be clean, dry and free of grease before bonding.
Properties
- Physical Properties
Value Units Test Method / Conditions Density (A/B, Liquid state) 1.07 g/cm³ - Mixing Ratio (Liquid State) 1:1 - - Open Time (Liquid State) 2 - 4 minutes - Fixture Time (Liquid State) 5 - 10 minutes - Flashpoint (Liquid State) 10.0 °C - Viscosity (Cone/plate, at 20°C at 0.5 s⁻¹) 80.000 - 140.000 mPa.s - Hardness 70 - 80 Shore D Full Cure Time (Polymer) 24.0 hours - Temperature Range (Polymer) -50 - 120 °C - Elongation at Break (Polymer) 30 - 40 % - E-Modulus (Polymer) 800 - 1200 MPa - Tensile Strength (Polymer) 20 - 30 MPa -
Regulatory & Compliance
- Certifications & Compliance
Technical Details & Test Data
- Technical Information
Adhesive performance -Tensile Shear Strength Substrate N/mm² Tensile shear strength (Polycarbonate,Fail) 6 - 10 Tensile shear strength (PMMA, Fail) 5 - 10 Tensile shear strength (ABS, Fail) 7 - 11 Tensile shear strength (PVC, Fail) 8 - 12 Tensile shear strength (Stainless steel) 23 - 26 Tensile shear strength (Aluminum) 14 - 20 Tensile Shear Strength
Hot Strength Tested at Temperature
Resistance Against Solvents
Solvent Resistance Weak acids very good Weak bases very good Polar solvents limited Strong acids and bases limited Measurement of Viscosity
Viscosity describes the flow-ability of a liquid. Cyberbond measures the viscosity of the products by means of the cone/plate method: the liquid is applied on a panel and a defined cone presses the liquid together and rotates. Newtonian fluids are measured at shear rate 160 s-1, thixotropic products are measured at shear rate 0,5 s-1 and 160 s-1. The viscosity is measured in mPa*s at 20 °C.
Safety & Health
- Safety Information
- Keep the workplace clean and use in well ventilated areas only. Installll suitable exhaust system at the workplace.
- Wear suitable safety glasses and gloves.
- Keep away from heat, hot surfaces, sparks, open flames and other ignition sources.
Packaging & Availability
- Packaging Type
- Regional Availability
Storage & Handling
- Shelf Life
- 12 Months
- Storage Conditions
Store products in a cold and dark place at temperatures between 10 °C to 20 °C.