Enhanced TDS
Identification & Functionality
- Product Type
- Technologies
- Product Families
- Product Image
- Base Polymer (Cover & Tape)
Polymer blend/TPO
Features & Benefits
- Product Highlights
Features Benefits Quick and easy Installation Saves time and labor
Eliminates fastening through membrane Minimizes leak potential
Eliminates membrane bridging Extends membrane service life
No torches or liquid adhesives required Improved safety
Applications & Uses
- Markets
- Applications
- Application Area
- Recommended Applications
Cool Cover™ Reinforced TPO Perimeter Strip is designed for non-penetrating securement of the TPO membrane in ballasted, fully adhered, and mechanically fastened roof systems.
- Application Methods
- Place the Cool Cover™ Reinforced TPO Perimeter Strip horizontally or vertically in the angle change with the pre-applied tape in the horizontal position and facing up.
- Installll seam fastening plates and screws, a maximum of 12” (30.48cm) o.c. Use fastener placement markings on TPO sheet as a guide.
- Clean portion of TPO field membrane that will be adhered over Cool Cover™ Reinforced TPO Perimeter Strip.
- Apply Millennium Single-Ply Primer or Millennium Primer 240 on portion of TPO field membrane that will be adhered to the Perimeter Strip utilizing the supplied pad. Scrub the membrane in a circular motion.
- Allow the primer to dry to the touch (no material transfer), typically less than 20 minutes. Dry time will vary depending on ambient temperature and humidity.
- Once the primer is dry immediately installll TPO membrane. Remove release liner and set the TPO membrane onto the Cool Cover™ Reinforced TPO Perimeter Strip and press in by hand.
- Once the release liner has been removed, reinforce the field membrane to tape bond by rolling with a 2”(5.08cm) wide silicone roller. NOTE: The adhesive tape will continue to build bond strength to the primed TPO for several hours after installation.
- Gently pull the TPO field membrane back to the adhered tape line to expose the un-adhered portion of the TPO field membrane. Install TPO membrane manufacturer’s recommended bonding adhesive to the parapet wall, the exposed mechanically fastened portion of the Cool Cover™ Reinforced TPO Perimeter Strip, and to the underside of the field membrane.
- Once adhesive has dried roll the field membrane in place for 100% adhesion through the elevation transition.
Surface Preparation
All work surfaces should be clean, dry, and free of dirt, dust, debris, oils, un-adhered coatings, deteriorated membrane and other contaminants that may result in a surface that is not sound or is uneven.
- Limitations
- Not to be used without mechanical fasteners.
- Not for use with PVC membrane.
- Talc dust, oil, ice, snow or wet conditions inhibit good adhesion to the pressure sensitive tape. Clean and dry surfaces are necessary for proper Installation of this product.
Properties
- Color (Properties)
- Typical Properties
Value Units Test Method / Conditions Peel Strength (at 21°C) 20.0 pli ASTM D 413 Shear Strength (at 21°C) 50 - 60 psi ASTM D 816 Brittleness Temperature -60 to -70 °C ASTM D 7426
Packaging & Availability
- Regional Availability
- Packaging and Coverage
Millennium Reinforced TPO Perimeter Strip is available in the following size:
North America
Width Length Part # Rolls/Case 6 inch (152mm) 100 ft. (30.40m) ET-9006 2 Europe, CIS, and Middle East
Width Length Part # Rolls/Case 6 inch (152mm) 100 ft. (30.40m) ET-9006 - EU 2
Storage & Handling
- Shelf Life
- 24 Months
- Storage Conditions
Store material in original unopened packaging at temperatures between 40°F-110°F (4°C - 43°C). Shelf life is 24 months when stored as recommended.