Enhanced TDS
Identification & Functionality
- Backing Material Type
- Product Type
- Technologies
- Product Families
- Product Image
- Base Polymer (Cover & Tape)
- Base - EPDM
- Test Method - FTIR
Features & Benefits
- Ready-to-Use Product Features
- Key Attributes
Features Benefits Resistant to UV light, high heat and moisture Long-term durability
Excellent adhesion to multiple substrates Suitable for a wide variety of sealing applications
No torch or liquid adhesives Improved safety Fast Installation Saves time and labor
Waterproof detail Suitable for roofing, pond lining, and waterproofing applications
Applications & Uses
- Markets
- Applications
- Application Area
- Basic Use
Millennium EPDM Cover Strips are designed to cover, protect, and seal mechanical fastening bars, membrane fasteners, core sample repair patches, membrane repairs, metal edge tie-in, and seam overlays in all EPDM roofing systems.
- Application Method
1. Clean entire surface where Millennium EPDM Cover Strip will be applied.
2. Apply Millennium Single-Ply Primer or Millennium Primer 240 (LVOC) to entire surface to be covered using the supplied scrub pad. NOTE: Use caution when installlling at temperatures below 40°F (4°C) to prevent blushing of EPDM primer (formation of condensation on surface of primer).
3. Allow the primer to dry to the touch (no material transfer, typically less than 20 minutes). Dry time will vary depending on ambient temperature and humidity.
4. Once the primer is dry immediately install Millennium EPDM Cover Strip.
5. Position Cover Strip over primed area and remove release liner at 45 degree angle while pressing down cover strip by hand.
6. Roll the Cover Strip with a 2” (5.08cm) wide silicone roller. 7. Seal edges of cover detail with patented Millennium EPDM Edge Sealant.*
*US 6,642,296 B2; US 6,291,571 B1
- Surface Preparation
All work surfaces should be clean, dry, and free of dirt, dust, debris, oils, un-adhered coatings, deteriorated membrane and other contaminants that may result in a surface that is not sound or is uneven. If necessary, clean the surface to receive the flashing with an approved EPDM membrane cleaner.
- Limitations
- Not for use on PVC roof membranes.
- Talc, dust, oil, ice, snow, or wet conditions inhibit good adhesion.Clean and dry surfaces are necessary for proper Installation of this product.
- Note
The foregoing information is published as general information only. The listed properties and performance characteristics are typical values and are not to be interpreted as manufacturing specifications.
Properties
- Color (Properties)
- Typical Physical Properties
Value Units Test Method / Conditions Tensile Strength min. 900 psi ASTM D 412 Elongation 300.0 % ASTM D 412 Tear Resistance 125.0 lbs./in ASTM D 624 Ozone Resistance No Cracking - ASTM D 4419 Peel Strength (at 21°C) 10.0 pli ASTM D 413 Shear Strength (at 21°C) 20.0 psi ASTM D 816 Brittleness Temperature -46 °C ASTM D 2137
Packaging & Availability
- Packaging Type
- Regional Availability
- Packaging and Coverage
Millennium EPDM Seam Tape is available in the following sizes:
North America
Width Length Part # Rolls/Case 5 inch (127mm) 100 ft. (30.48m) ET-0911-05CC 2 6 inch (152mm) 100 ft. (30.48m) ET-0911-06CC 2 9 inch (229mm) 100 ft. (30.48m) ET-0911-09CC 1 12 inch (305mm) 50 ft. (15.24m) ET-0911-12CC 1 18 inch (457mm) 50 ft. (15.24m) ET-0911-18CC 1 Europe , CIS and Middle East
Width Length Part # Rolls/Case 5 inch (127mm) 100 ft. (30.48m) ET-0911-05EU 2 6 inch (152mm) 100 ft. (30.48m) ET-0911-06EU 2 9 inch (229mm) 100 ft. (30.48m) ET-0911-09EU 1 12 inch (305mm) 50 ft. (15.24m) ET-0911-12EU 1 18 inch (457mm) 50 ft. (15.24m) ET-0911-18EU 1
Storage & Handling
- Shelf Life
- 24 Months
- Storage Conditions
Store material in original unopened packaging at temperatures between 40°F-110°F (4°C - 43°C). Shelf life is 24 months when stored as recommended.