H.B. Fuller FH8008
1 of 389 products in this brandChemical Family: Epoxy & Epoxy Derivatives
RTU Product Type: 1K (1 component) Adhesive, Reactive Adhesive, Underfill Adhesive
Application Area: Electronic Components
Features: Excellent Filling Properties, Fast Cure, Good Gap Filling Capabilities, High Reliability
Enhanced TDS
Identification
- Chemical Family
- GBU
- RTU Product Type
- Categories
Application Information
- Cure Method
Applications
- Application Area
Applications & Uses
- Clean-Up
-
Equipment, brushes, and spillage can be cleaned promptly after use with a mixture of anhydrous isopropyl alcohol and acetone that should be discarded after each use.
- Preparation for Material Usage
-
1. Do not open the package before complete the thawing.
2. Thawing to room temperature (25°C) before using.
3. Seal any remaining material and store immediately at -18℃.
4. We do not recommend thawing material more than three times.
Features
- Ready-to-Use Product Features
Features & Benefits
- Features and Benefits
-
- Fast cure at moderate temperature minimizing stress on components.
- Reworkable without damage to the attach pad
- High reliability design for portable device
- Single Component
Packaging & Availability
- Regional Availability
Physical Properties
- Color (Properties)
Properties
- Density:
-
1150 kg/m³
- Dielectric Strength:
-
25 kV/mm
- Specific Gravity:
-
1.15
- Typical Properties
-
Value Units Test Method / Conditions Storage Temperature -18 °C - - Uncured Properties
-
Value Units Test Method / Conditions Specific Gravity 1.15 - - Viscosity (at 25°C, 100 rpm) 510 cPs - Working Pot Life 3 days - - Cured Properties
-
Value Units Test Method / Conditions Coefficient of Thermal Expansion (cured at 120C°, 30 min, alpha 1) 89 m/m.°C ASTM E831 Coefficient of Thermal Expansion (cured at 120C°, 30 min, alpha 2) 226 m/m.°C ASTM E-831 Cure Time (at 150°C) 8 minutes - Transition Temperature (cured at 120C°, 30 min) 108 °C - - Electrical Properties
-
Value Units Test Method / Conditions Dielectric Strength 25 kV/mm ASTM D-149 Surface Resistivity 12000000000000000 ohm ASTM D-257 Volume Resistivity 41000000000000000 Ω-cm ASTM D-257
Storage & Handling
- Storage Conditions
-
FH8008 is supplied in 30ml/syringes
It should be stored in a -18°C refrigerator.
Shelf life is 6 months from date of manufacture. - Shelf Life
-
6 months
Technical Details & Test Data
- Curing Profile
-
- Recommended cure conditions:
- 8 minutes @ 150℃
- Curing speed will vary depending on oven temperatures profile efficiency, printed circuit board thickness
- Recommended cure conditions: