Enhanced TDS
Identification & Functionality
Features & Benefits
- Labeling Claims
- Ready-to-Use Product Features
- Features and Benefits
- One component, requires no mixing
- Excellent depth of cure, fast curing
- Excellent adhesion to glass, many plastics and many metals
- High flexibility
- Excellent depth of cure
- Color changed after UV cured
- Tack free surface finish
- Excellent precision dispensing and jetting performance
- Excellent electrical insulation performance
- Halogen free
Applications & Uses
- Markets
- Applications
- Application Area
- Compatible Substrates & Surfaces
- Instruction for Use
1. Coating surface area should be clean and free of any fluxes, residues, dust or any other contaminants.
2. A UV lamp with a wavelength of 365nm is required. The UV light should be focused towards the coated surface.
3. Curing speed is determined by the intensity of UV radiation, the distance from the UV light source and the coating surface. The depth of coating material can also require additional cure time.
4. Immediately close the lid after use. A black hose must be used to dispense the adhesive.
5. This material should be stored away from sunlight, UV light and artificial light sources.
Properties
- Color (Properties)
- Physical Form
- Appearance
- Blue liquid
- Physical Properties of Cured Material
Value Units Test Method / Conditions Hardness (100 mW/cm², at 365 nm, 24s) 66.0 - Shore D Tensile Strength (at Break, 100 mW/cm², at 365 nm, 24s) 16.0 MPa - Elongation at Break (100 mW/cm², at 365 nm, 24s) 155.0 % - Lap Shear Strength (Polycarbonate - Polycarbonate, 100 mW/cm², at 365 nm, 24s) 14.0 MPa - Glass Transition Temperature (by TMA, 100 mW/cm², at 365 nm, 24s) 93.0 °C - - Cured Properties
Value Units Test Method / Conditions Specific Gravity 1.05 - - Cure Time (at 100 mW/cm²) 30.0 s - Optimum Wavelength 365 - 405 nm - - Uncured Properties
Value Units Test Method / Conditions Viscosity (25°C, CP52, 100 rpm) 5000.0 cP - Thixotropic Index 2.3 - - Density 1.05 g/cm³ - - Typical Cured Properties
Value Units Test Method / Conditions Tack Free Time (100 mW/cm², at 365 nm) max. 6 s - Depth of Cure (100 mW/cm², at 365 nm, 24sec) 8.0 mm -
Technical Details & Test Data
- Curing Profile
Recommended cure:
- 100mW/cm2 @ 405nm for 30s
Safety & Health
- Health and Safety Precautions
Keep away from children's store.
This product is recommended to be used within a well-ventilated place.
If you accidentally touches the skin, immediately wash with soap and water.
If you accidentally touches the eyes, please rinse with plenty of water, and then seek medical attention.
Packaging & Availability
- Regional Availability
Storage & Handling
- Storage Conditions
Product should be stored at temperature between 8℃ to 28℃ in the unopened container in a dry location.