- S.M. ADHESIVE is designed for use in applications where fibrous glass insulation is bonded to the interior or exterior of sheet metal air conditioning ducts.
- S.M. ADHESIVE meets ASTM C916, Type IV (ASC-A-7001- A, Type IV) and NFPA 90A and 90B 25/50 requirements.
- S.M. ADHESIVE is produced under the classification and follow-up service of Underwriter’s Laboratories, Inc.
Applications & Uses
- Application Area
- Application Method
- Preparation and Application Information
Material Preparation
DO NOT THIN. Stir well, but do not use sticks or boards, which would splinter or otherwise contaminate the product. No need to prime aluminum or galvanized metal. Apply only to clean, dry surfaces. Keep container closed when not in use to prevent solvent evaporation.
Application
Brush
Use a clean paintbrush. Uniformly, apply to metal surface at 200 – 400 sq. ft./gal. (4.9 – 9.8 m2 /l). Press insulation into place, making sure complete contact is made with applied adhesive. Bond may be made within 0 to 15 minutes.
Spray
May be spray applied with conventional air atomizing equipment or airless spray equipment. For spray equipment information, please consult spray recommendations or contact your spray equipment supplier. Average viscosity range: 200 – 500 cps.
Clean Up
Use solvents such as chlorinated solvent (non-flammable) or mineral spirits (flammable) for cleaning brushes and equipment.
- Limitations
- Always test plastic materials for compatibility when using solvent-based products.
- Make certain this product is completely dry and the area free from solvent odor if food is involved.
- Not suggested for sealing vapor barrier jackets.
- Allow to dry to a solvent-free condition before installing weld pins.
- Overhead applications may require mechanical fasteners.
Properties
- Physical Form
- Typical Properties
Value Units Test Method / Conditions Average Weight / U.S. Gallon 6.2 lbs. ASTM D1475 Average Non-Volatile (by Volume) 17 - 19 % ASTM D2369 Average Non-Volatile (by Weight) 27 - 30 % ASTM D2369 Coverage Range 200 - 400 sq. ft./gal. - Bonding Time Range 0 - 15 Minutes - Flash Point -7 °F - Application Properties
Value Units Test Method / Conditions Service Temperature Limits (at coated surface) -20 to 200 °F - Flame Characteristics
Value Units Test Method / Conditions Flame Spread ¹ 10 ASTM E84 Smoke Developed ¹ 25 ASTM E84 - Note
¹ - Tested at coverage rate of 200 sq. ft./gal. Applied to 1/4 inch (6.4 mm) inorganic reinforced cement board. The flame spread may vary at different product thicknesses and/or when applied over other surfaces.
Regulatory & Compliance
Storage & Handling
- Storage Condition
Store and apply between 40°F and 100°F.