Enhanced TDS
Identification & Functionality
- Product Type
- Technologies
- Product Families
Features & Benefits
- Ready-to-Use Product Features
- Product Highlights
- Foster® Protektor® Sealant 32-21 is a single-component, penetrating encapsulation coating for abating asbestos fiber fallout (retention method).
- Foster® Protektor® Sealant 32-21 penetrates deeply into the asbestos containing materials, and then dries to form a firm, lightweight, damage-resistant surface.
Applications & Uses
- Application Area
- Application Method
- Compatible Substrates & Surfaces
- Preparation and Application Information
Application – as an Encapsulant
Assess the adhesive/cohesive strength of the intended matrix to ensure sufficient integrity to accept the added weight of the encapsulant in the wet state using methodology based on ASTM E736. Once the integrity of the intended matrix is assured, in an esthetically unsensitive area, conduct a penetration test. Apply Foster® Protektor® Sealant 32-21 to the candidate matrix using a trigger-type spray apparatus or garden sprayer and saturate the matrix. Since absorption is a time related phenomenon, multiple passes are required, allowing time between passes for the dissipation of the encapsulant into the matrix. Full saturation is defined as the point where a given ACM will not, under the particular circumstances, absorb any more encapsulant into the matrix. Waiting no less than 8 hours, nor more than 24 hours, a second application of encapsulant is made to the same area in the same manner until full saturation is achieved for a second time. After allowing for full cure of the applied matrix, secure a core sample and evaluate for depth of penetration. Submerge the core sample in water for four hours. Remove the sample from the water and with a pointed instrument, starting from the substrate end of the core, scrape the plug removing those segments not solidly bound by the encapsulant. The remaining plug length is the effective depth of penetration. NOTE: If the candidate matrix shows any indication of loss of adhesion to the substrate or cohesive strength, or if the Foster® Protektor® Sealant 32-21 fails to achieve any level of penetration, it must be assumed that the candidate matrix is not suitable for encapsulation. Having determined that the candidate matrix is a viable recipient, apply the first coat of Foster® Protektor® Sealant 32-21 to the intended matrix (using airless spray as indicated below) until saturation is achieved. Multiple passes at varying intervals may be required. Wait no less than 8 hours or more than 24 hours and apply a second coat in the same manner as the first.Application – as a Lockdown
Apply Foster® Protektor® Sealant 32-21 using airless spray equipment as indicated below, directly to the exposed substrate from which the ACM has been removed in a continuous manner at an application rate of 400 – 600 sq. ft./gal (9.8 – 14.7 m2/l) (steel surface). Porous or uneven surfaces may require additional material. CONSULT APPLICABLE OSHA AND EPA REGULATIONS.Floors
Foster® Protektor® Sealant 32-21 is not suggested as a floor traffic coating. It may be used on floors provided that a new floor surfacing material is installlllllllllllled over it. Flooring installers must determine by their own tests that any mastic, adhesive or cement they plan on using is compatible with, and bonds firmly to, the dried Foster® Protektor® Sealant 32-21.Spray Equipment
High output, electric, airless spray equipment is ideal, but pneumatic or hydraulic can be used. Foster® Protektor® Sealant 32-21 can be applied with virtually any type of airless spray equipment on the market today capable of spraying water-based paint. Pressure settings should be set as low as possible while still achieving atomization. Average viscosity range: 5 – 20 cps.Clean Up
Use fresh water to clean equipment before product dries. Dry product may be removed with hot soapy water or strong solvents such as chlorinated solvent (non-flammable) or xylol (flammable).
Properties
- Physical Form
- Odor
- Mild when wet; none when dry
- Typical Properties
Value Units Test Method / Conditions Weight/U.S. Gallon 8.5 lbs ASTM D1475 Wet Flammability 96.0 °C - Coverage Range 0.82 - 4.07 l/m² - Solids 9.5 % by Weight - VOC Content 0.2 % by Weight - Specific Gravity 1.01 - - - Application Properties
Value Units Test Method / Conditions Service Temperature Range -29 to 121 °C - - Flame Characteristics
Value Units Test Method / Conditions Surface Flame Spread¹ 15.0 ASTM E162 Smoke Developed¹ 0 ASTM E162 - Note
Applied to 1/4 inch (6.35 mm) inorganic reinforced cement board at a coverage rate of 10 gal./100 sq. ft. (4.07 l/m2 ).
Regulatory & Compliance
- Certifications & Compliance
- Chemical Inventories
- Quality Standards
Storage & Handling
- Shelf Life
- 12 months
- Handling Conditions
- As an Encapsulant – do not store or apply below 40°F (4°C) or above 100°F (38°C). Protect from freezing until dry.
- Do not apply to surfaces operating at, or intended to operate at, temperatures in excess of 250°F (121°C).