Cyberbond CB AT 6085

1 of 84 products in this brand
Cyberbond CB AT 6085 is a two component methyl methacrylate adhesive. It is especially suited for bonding metals to different plastics (e.g. ABS, PC, PVC, PMMA, Polyamide) and composites. Cyberbond offers these adhesives in double cartridges in 1:1 or 10:1 ratio with static mixing tubes. This allows an easy and quick application.

Product Type: 2K (2 component) Adhesive, Anaerobic Adhesive, Anaerobic Sealant, Reactive Adhesive

Compatible Substrates & Surfaces: Acrylonitrile Butadiene Styrene (ABS), Composites, Metal, Plastics, Poly(Methyl Methacrylate) (PMMA), Polyamide, Polycarbonate (PC), Polyvinyl Chloride (PVC)

Chemical Family: Acrylics, Acrylates & Methacrylates

Features: Good Adhesion, Weak Acid Resistant, Weak Base Resistant

Technical Data Sheet

Enhanced TDS

Identification & Functionality

Features & Benefits

Ready-to-Use Product Features
General Information about MMA Adhesives

2-component methacrylate adhesives belong to the group of reactive adhesives. The reaction starts by mixing hardener and resin. Cyberbond offers these adhesives in double cartridges in 1:1 or 10:1 ratio with static mixing tubes. This allows an easy and quick application. Methacrylate adhesives are available in different viscosities from liquid to paste-like and with different curing times. They are characterized by excellent adhesion to metals, many plastics and composite materials. The mechanical properties range from flexible to rigid.

Applications & Uses

Properties

Component A
ValueUnitsTest Method / Conditions
Density (Liquid state)1.07g/cm³-
Physical Properties
ValueUnitsTest Method / Conditions
Mixing Ratio (Liquid State)10:1--
Open Time (Liquid State)9 - 11minutes-
Fixture Time (Liquid State)5 - 10minutes-
Flashpoint (Liquid State)10.0°C-
Viscosity (Cone/plate, at 20°C at 160 s⁻¹)2.000 - 6.000mPa.s-
Viscosity (Cone/plate, at 20°C at 0.5 s⁻¹)25.000 - 60.000mPa.s-
Full Cure Time (Polymer)24.0hours-
Temperature Range (Polymer)-50 - 120°C-
Elongation at Break (Polymer)15 - 30%-
E-Modulus (Polymer)800 - 1200MPa-
Tensile Strength (Polymer)14 - 18MPa-
Component B
ValueUnitsTest Method / Conditions
Density (Liquid state)1.14g/cm³-

Technical Details & Test Data

Technical Information
Adhesive Performance Tensile Shear Strength
Substrate N/mm²
Tensile shear strength (Polycarbonate,Fail) 9 - 11
Tensile shear strength (PMMA, Fail) 7 - 10
Tensile shear strength (ABS, Fail) 8 - 10
Tensile shear strength (PVC, Fail) 8 - 10
Tensile shear strength (Stainless steel) 11 - 15
Tensile shear strength (Aluminum) 7 - 10

 

Tensile Shear Strength

Cyberbond CB AT 6085 - Technical Information

 

Hot strength Tested at Temperature

Cyberbond CB AT 6085 - Technical Information - 1

 

Resistance Against Solvents

Solvent Resistance
Weak acids very good
Weak bases very good
Polar solvents limited
Strong acids and bases limited

 

Measurement of Viscosity

Viscosity describes the flow-ability of a liquid. Cyberbond measures the viscosity of the products by means of the cone/plate method: the liquid is applied on a panel and a defined cone presses the liquid together and rotates. Newtonian fluids are measured at shear rate 160 s-1, thixotropic products are measured at shear rate 0,5 s-1 and 160 s-1. The viscosity is measured in mPa*s at 20 °C.

Safety & Health

Safety Information
  • Keep the workplace clean and use in well ventilated areas only. Installll suitable exhaust system at the workplace.
  • Wear suitable safety glasses and gloves.
  • Keep away from heat, hot surfaces, sparks, open flames and other ignition sources.